Skip to content

FACILITY DIRECTORY

T5 Data Centers

T5 Data Centers - T5@Silicon Valley

39800 Eureka Dr, Newark, California, United States

Availability to confirmRecord under review

A clearer view of this location.

T5 Data Centers - T5@Silicon Valley is a directory record in Newark. Use the information below as a starting point, then confirm the facility scope, technical requirements and availability.

Reported operator
T5 Data Centers
Critical IT power
17 MW
Currently available IT power
Confirm by enquiry
Reported rack density
Not confirmed
Reported cooling
air
Deployment date
Confirm by enquiry

Reported power is not available capacity. The source notes identify reviewed specifications; other imported details remain unconfirmed.

Location

1 mapped locations

Locations are approximate directory positions. Select a cluster to explore.

39800 Eureka Dr, Newark, California, United States

Search this address in Google Maps ↗

Record information

Evidence reviewed: Oct 20, 2026

Source record updated
May 5, 2026
Directory import
Aug 17, 2026
Current availability verification
Not supplied

Source-update and import dates describe the record’s history. They do not confirm current specifications or available capacity.

View sources and review notes

The dated operator announcement explicitly separates the existing building and its 17 critical MW from a future 32.1 MW/180,000-square-foot addition. Its later facility sheet still calls 49.1 MW campus expansion plans; historical 8.5 MW Q2 2023 availability is not current inventory. The T5 organization’s facility entry on PeeringDB links the operator facility page and supplies 39800 Eureka Drive, matching this row; registry self-report is distinguished from government verification. Municipal and OSHA exact-address leads returned 403 and are not used as inspected evidence. The brochure page 2 was visually reviewed: 128,000 square feet existing and indirect evaporative cooling. Keep the existing near-building point; Census street interpolation is less precise here and is not substituted. Clear 2020 build year because the dated source establishes acquisition of a previously enterprise-owned data center, not new construction in that year. Current unleased power remains unknown. The inherited generic Tier III and PUE 1.4 claims are not established by the reviewed site evidence and are cleared; Uptime management awards do not establish Tier certification. Unchanged imported fields are not globally certified.

Suggest a listing correction ↗